2V1 & 3V1 Series Solenoid Valve Specifications and Dimensions

Part No.

Unit Price

Valve Picture

Port Size
(NPT)

Voltage  Options

Electrical Entry Options

Port No/ Position/Solenoid

Cv
Flow Rate

Response Time

Power Consumption

Pneumatic Symbo

2V1 1/8

$18.81*

1/8 NPT

1=12VDC
2=24VDC

2A=24VAC
3=110VAC
4=220VAC
(50/60Hz)

G=Grommet

D= DIN (with LED indicator)

2/2/1
Direct Acting 
Normally closed 
Two Way Valve

S
TACKING

0.23
22 SCFM @100 PSI

< 20 ms

3W for 60PSI

4.8W  for 115 PSI

6.5W  for 150 PSI

3V1 1/8

$18.81*

1/8 NPT

1=12VDC
2=24VDC

2A=24VAC
3=110VAC
4=220VAC
(50/60Hz)

G=Grommet

D= DIN (with LED indicator)

3/2/1
Direct Acting 
Normally closed 
Three Way Valve

S
TACKING

0.1
5 SCFM @100 PSI

< 20 ms

3W for 60PSI

4.8W  for 115 PSI

6.5W  for 150 PSI

2V1 & 3V1 Series Valve Specifications 

Port & Mounting

Body Ported, Stackable ( Stacking Hardware Included)

Action & Motion

Direct Acting, Normally Closed, Two Position, 2 to 3 Way

Operating Pressure

28" Hg to 115 PSI (Coil Wattage Dependent)

Working Medium

40 micron filtered air, inert gas & liquid

Maximum Pressure

150 PSI

Operating Temperature

 (-5 to 80 Deg. C)  with non-freezing medium

Coil Insulation & Protection Class

F Class, IP65 (CE Certification)

Coil Duty Cycle

100% ED

Electrical Connection

D = DIN (with LED indicator, conduit terminal)
G = Grommet (12” Lead Wire)

Body Material

Anodized Aluminum

Seal Material

NBR (Buna N)

Lubrication

Not Required

Electrical Coil Connections
For DIN Coil

To connect DIN coil:
1. Remove the Philip screw from the plastic housing and unplug it from the DIN coil.
2. From the screw opening, push the terminal block out from the plastic housing.
3. Note the 1, 2 and ground markings on underside of DIN enclosure.
4. For DC DIN Coil, Connect 1 to Positive, 2 to Negative.
5. For AC DIN Coil, connect 1 to HOT wire, 2 to Neutral wire, and if required connect ground to ground wire.

For Grommet Coil

To connect Grommet coil:
1.  For DC Coil, connect one of the two wires to Positive, and the other wire to Negative.
2. For AC Coil, connect one of the two wires to HOT wire, and the other wire to neutral wire.

2V1 & 3V1 Series Solenoid Valve Dimensions

 * Includes Stacking Hardwares and seals
 
主页 气动接头 不锈钢接头 仪器阀 电磁阀 流体阀 球阀 气阀 气源处理器 气缸 条件 下载 诚聘精英 订货

想成为STC经销商,请致电 574 6250 6166, 或传真致 574  6250 0687, 或发电邮到 sales@StcCn.com   
 
© 2007-2012余姚 司徒气动元件有限公司 , 保持所有权. 修订日期: 2012 62  STC 让流体动力服务于工业自动化